Double-wall chimney system DW50M SAUNA

System is designed to exhaust combustion products by natural draught from a sauna stove.

Notes

Chimney system for particular cases must be selected according to the documentation of the heating appliance manufacturer, chimney installation guide and national legal acts.

Fuel

Dry wood

Working temperature

≤ 600 °C

Steel

Inner pipe: stainless steel EN 1.4307
Outer pipe: stainless steel EN 1.4307

Wall thickness

0,8 mm

Pressure class

N1 – natural draught

Isolation

Mineral wool, thickness – 50 mm

Sootfire resistance

G – resistant

Distance to combustible materials

≥ 1001 mm (designation 4)

Condensate resistance

D – designed for dry operating conditions

Certificates

1397-CPR-0558

System marking

EN 1856-1 T600-N1-D-Vm-L20080-G100 (4)

Catalog

Instruction

Declaration

Certificate

1 The actual minimum distance to combustible materials from the outer surface of a chimney must be defined according to the designation of the chimney, as described in their marking. and national legal acts. If the legal acts and chimney designation indicate different admissible distances of the combustible materials, it is necessary to follow a bigger distance. The distance to combustible materials determined for dn 200 mm diameter during the tests. The distance to combustible materials for chimneys larger that that tested must be increased by a factor. For dn 201-300 mm the factor must be 1 time the distance to combustible material determined for dn 200 mm, for dn 301-450 mm – 1,5, dn 451-600 mm – 2, above dn 601 mm – 4.