Double wall chimney system is designed to exhaust combustion products from heating appliances by natural draught.
Chimney system for particular cases must be selected according to the documentation of the heating appliance manufacturer, chimney installation guide and national legal acts.
Oil, gas, solid fuels
≤ 200 °C
≤ 450 °C
≤ 600 °C
Inner pipe: stainless steel EN 1.4404
Outer pipe: stainless steel EN 1.4301 or painted steel
When dn from 80 to 200 mm – 0,5, 0,6, 0,8, 1,0 mm
When dnfrom 230 to 550 mm – 0,6, 0,8, 1,0 mm
When dn from 600 to 900 mm – 0,8, 1,0 mm
N1 – natural draught
P1 – positive pressure (with gaskets)
Injected mineral wool, thickness – 50 mm
G – resistant
O – not resistant (with gaskets)
≥ 501 mm (designation 1)
≥ 801 mm (designation 2)
≥ 501 mm (designation 3)
≥ 1001 mm (designation 4)
W – designed for dry operating conditions
1397-CPR-0558
EN 1856-1 T600-N1-W-Vm-L50XXX-G50 (1)
EN 1856-1 T450-N1-W-Vm-L50XXX-G80 (2)
EN 1856-1 T200-P1-W-Vm-L50XXX-O50 (3)
EN 1856-1 T600-N1-W-Vm-L50XXX-G100 (4)
1 Faktiniai leistini minimalūs atstumai iki degiųjų medžiagų nuo dūmtraukio išorinio paviršiaus turi būti nustatomi atsižvelgiant į gaminio žymėjime bei nacionaliniuose teisės aktuose nurodytus atstumus. Jei teisės aktuose ir gaminio žymėjime minėti atstumai skiriasi, tada reikia vadovautis didesniu leistinu atstumu iki degiųjų medžiagų. Leistini minimalūs atstumai iki degiųjų medžiagų (mm) nustatyti bandant d 200 mm vidinio skersmens šios sistemos dūmtraukius. Atstumai iki degiųjų medžiagų didesniems negu išbandyti dūmtraukiams apskaičiuojami bandymais nustatytą atstumą padauginus iš šių koeficientų: kai d 201-300 mm, koeficientas 1, d 301-450 mm – 1,5, d 451-600 mm – 2, daugiau kaip d 601 mm – 4.